Filter Results By:

Products

Applications

Manufacturers

Calibration Standards

A qualified quantified source of known value.

See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Software, Calibration Services, Calibration References


Showing results: 391 - 405 of 408 items found.

  • Noise Dose Meters

    PCE Instruments

    Here you will find a full range with an industrial standard noise dose meter to suit every requirement. With the portable noise dose meter you can carry out measurements quickly to gain control of a situation or to set the device to take timed measurements. The noise dose meter is important for all industries, especially by using it as a mobile device which is able to assess office stress levels or street noise levels.Often problems arise from noisy neighbors or if bars and restaurants are in residential areas and produce noise levels after 10pm in excess of what local laws permit. We, of course, can assess which noise dose meter you require in relation to the issue you have and the relating laws. We also have microphone extension cords, tripods, calibrators and calibration certificates for most models of noise dose meter.

  • Bulk Current Monitoring Probe

    MP-50 - FRANKONIA GmbH

    The Current Monitoring probes may be used whenever RF current measurements are required. Current measurements are made by placing a current carrying conductor within the “sensing” window of the probe and measuring the probe’s output voltage with an RF detector. Calibration of the probe permits the conversion of the voltages measured to current. Current measurements can be made over the frequency range shown in the transfer impedance curve furnished with each probe. There is virtually no loading of the circuit and the technique permits normal operation of the device under test during measurements. The MP-50 can be used for the procedure for clamp injection when the common- mode impedance requirements cannot be met given in chapter 7.4 of IEC/EN 61000-4-6 „Immunity to conducted disturbances, induced by radio frequency fields”. The MP-50 can also be used as current monitor for BCI testing as per ISO11452-4, RTCA/DO-160 section 20, MIL-STD-461 and various automotive standards.

  • Compact, High-resolution Thermographic Camera

    Ceres T 1280 Series - Xenics

    The Ceres T 1280 series is based upon the Dione 1280 OEM thermal imaging core with 1280×1024 pixels and 12 µm pixel pitch and NETD of less than 50 mK. The camera offers superior on-board thermographic performance (accuracy, stability) in the temperature range up to 400 °C.The Ceres T 1280 camera outputs full frame images at 60 Hz via either a CameraLink or at 45 Hz via GigE Vision interface – all GenICam compliant.The compact size and excellent thermographic stability and accuracy, and GenICam compliant interfacing allow for easy integration in demanding industrial thermography applications.The camera offers one standard option of lens and thermal calibration pack.Benefits & Features• Compact and high-resolution• Superior on-board thermographic performance (stability, accuracy)• GenICam compliant• Uncooled operation

  • Active Monopole Antenna

    AM-741 - Com-Power Corporation

    The 41 inch Monopole antenna is required for making electric field emission measurements below 60 MHz per Military standards (MIL-STD-461) and FAA (DO-160) specifications. This antenna is for emissions measurements only. It cannot be used for transmitting. The Active Monopole antenna is generally used in a shielded room or in a screen room, with the equipment under test (EUT) placed on a metal ground plane. The 41 inch rod and the ground plane behave electrically as though a mirror image of the rod were located below the ground, and the ground removed. Since the stainless steel plate does not have enough surface area to mirror the entire 41 inch rod, it is bonded to the surrounding ground plane during use. The AM-741 is battery powered to prevent measurement errors that maybe caused by external power cables. The ANSI equivalent capacitance substitution (ECSM) method is the recommended method for calibrating AM-741 monopole antenna. The individual calibration data will be included with each antenna.

  • Luminance Colorimeter

    XYL-VI - Lisun Electronics Inc.

    The XYL-VI Luminance Photoelectric Colorimeter changes the traditional structure thoroughly, employs the digital X(λ), Y(λ), Z(λ) sensors to replace the traditional analogue sensors, employs the digital signal measurement system to replace the traditional analogue measurement system. The instrument has no analogue unit, thus it is very simple to overcome the zero drift that is impossible to be avoided in traditional colorimeter. The digital sensor has a large dynamic range. Moreover, it possesses strong anti-interference ability and it has high accuracy. The XYL-VI Luminance Colorimeter contains internal RS232 computer interface. The calibration is done by software. It is suitable for monitoring and remote applications. The XYL-VI Luminance Colorimeter can be calibrated by XYL-VI Luminance Colorimeter software to sample the data and print out the results. It can also be corrected by other standard light sources to obtain very high measuring accuracy of x, y color coordinates and color temperature. It is a real-time measuring system and run under Windows2000/XP.

  • High-Resolution Thermographic Camera

    Ceres T 640 Series - Xenics

    The Ceres T 640 series is based upon the Dione 640 OEM thermal imaging core with 640×480 pixels and 12 µm pixel pitch and NETD of less than 50 mK. The camera offers superior on-board thermographic performance (accuracy, stability) in the temperature range up to 400 °C.The Ceres T 640 camera outputs full frame images at 60 Hz via either a CameraLink or GigE Vision interface – all GenICam compliant.The compact size and excellent thermographic stability and accuracy, and GenICam compliant interfacing allow for easy integration in demanding industrial thermography applications.The camera offers one standard option of lens and thermal calibration pack.The compact Ceres T 640 series find application in process monitoring, medical and scientific and advanced research.Benefits & Features• Compact size and high-performance• Superior on-board thermographic performance (stability, accuracy)• GenICam compliant• Uncooled operation

  • Digital Colorimeter & Illuminance Meter

    CHC-I - Lisun Electronics Inc.

    This Digital Color Meter & Illuminance Meter is based on all digital integral photometric and colorimetric measurement technology. It has no analogue unit, thus it is very simple to overcome the zero drift which is impossible to be avoided in current colorimeter. The digital X (λ), Y (λ), Z (λ) sensor has large dynamic range so that there is no range-changing error in it; moreover, it possesses strong anti-interference ability and high accuracy. The CHC-I contains internal RS232 computer interface, the calibration is done by software. It is suitable for monitoring and remote applications. The CHC-I software can calibrate the instrumentation, sample the data through RS232 interface and print out the results. It can also be calibrated by other standard light sources to obtain very high measuring accuracy of x, y color coordinate and color temperature. It is a real-time measuring system and run under Windows System. 128*64 lattice LCD display, RS232 computer interface and software, Data hold function.

  • Fully Automatic Colorimeter

    DRK103C - Shandong Drick Instruments Co., Ltd.

    (1)5 inch TFT color LCD touch screen, the operation is more humanized, new users can be mastered in a short period of time using the method.(2)Simulation of D65 lighting lighting, using CIE1964 complementary color system and CIE1976 (L*a*b*) color space color difference formula.(3)The motherboard brand new design, using the latest technology, CPU uses 32 bits ARM processor,improve the processing speed, the calculated data is more accurate and rapid electromechanical integration design, abandon cumbersome testing process of the artificial hand wheel is rotated, the real implementation of the test program, a determination of the accurate and efficient.(4)Using d/o lighting and observation geometry, diffuse ball diameter 150mm, diameter of the testing hole is 25mm.(5) A light absorber, eliminate the effect of specular reflection.(6)Add printer and imported thermal printer, without the use of ink and color, no noise when working, fast printing speed.(7) Reference sample can be physical, but also for data,? Can store up to ten only memory reference information.(8) Has the memory function, even if the long-term shutdown loss of power, memory zeroing, calibration, standard sample and a reference sample values of the useful information is not lost.(9) Equipped with a standard RS232 interface, can communicate with computer software.

  • Noise Meters

    PCE Instruments

    Here you will find a full range with an industrial standard noise meter / sound meter to suit every requirement. With the portable noise meter you can carry out measurements quickly to gain control of a situation or to set the sound meter to take timed measurements. The noise meter is important for all industries, especially by using it as a mobile noise meter which is able to assess office stress levels or street noise levels. Often problems arise from noisy neighbors or if bars and restaurants are in residential areas and produce noise levels after 10 pm in excess of what local laws permit. A noise meter / sound meter will help here.We can assess which noise meter or sound meter you require in relation to the issue you have and the relating laws (requirements regarding a sound meter and a sound meter’s usage vary depending on the country). We also have noise meter microphone extension cords, tripods, sound meter calibrators and calibration certificates for most noise meter models.

  • Loss Meter

    L2000 - Appointech, Inc.

    3-in-1 as loss meter, light source, and power meter As loss meter Measure fiber loss at 1310nm and 1550nm As light source Single-head selectable output wavelength of 1310 or 1550 nm Ultra high output stability 0.05dB High output power preset at 0 dBm, or at customer-defined value Selectable CW, 270 Hz, 1KHz or 2KHz modulated output As power meter Calibrated outputs at 850, 1310, 1490, 1550, and 1625nm Data storage, logging, and PC up-loading Interactive measurements via PC Calibration on-site with customer's own standard if needed Selection of relative/absolute power measurement Display measurement in dB, dBm, mW, uW, nW Resolution 0.01dB; absolute accuracy 0.25dB For both single-mode and multi-mode optical fiber Small size, easy for field applications Light weight, less than 0.2Kg Auto power shut-off Enable / Disable Auto laser shut off at above 60oC Rechargeable battery, Battery-full and Battery-low indicator Changeable receptacle connector FC, SC, ST

  • Temperature Data Acquisition

    THERMES-USB - Physitemp Instruments

    Physitemp’s Thermes high accuracy data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB port or, with the included wireless receiver, positioned up to 100 feet from the host computer. Each unit will accommodate up to 7 type T thermocouple sensors and multiple Thermes units may be connected to the same computer for more thermocouple inputs. A high accuracy electronic cold junction compensation circuit maintains typical system accuracy of ±0.2°C over an ambient temperature range of 15 to 35°C. Individual offsets may be added to each input in software to facilitate individual calibration of each channel. (see THERMES-USB WFI)

  • Gas Analyzers

    Snap-on Inc.

    Independent Handheld 5 Gas Analyzer or use with MODIS™ Link, VERDICT® and VERUS® Bluetooth® link. Fully Portable 5 Gas Analyzer, go anywhere, use anywhere 110 V AC and 12 V powered Internal rechargeable battery, up to one hour of use Ideal for road testing and mobile use Measures exhaust emissions for CO, CO2, HC, O2, NOx and AFR/Lambda Provides an instant assessment of an engine vehicle exhaust and catalytic converter MODIS, VERDICT® and VERUS® Link for enhanced real-time viewing Setup required with included software on USB stick Gather all the evidence required for effective and accurate vehicle diagnostics on one screen in real time View, graph, save and recall data Monitor and reduce vehicle emissions, improve driveability and fuel efficiency There are 255 memory locations in the analyzer to track and print data for the same or many different vehicles Compatible with gasoline, CNG, propane and diesel fuel types Annual calibration and sensor replacement performed at Crystal Lake Northern Repiar enter Meets required industry standard

  • Temperature Data Acquistion

    THERMES-USB RF - Physitemp Instruments

    Physitemp’s original Thermes high accuracy ISA based data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB port or, with the included wireless receiver, positioned up to 100 feet from the host computer. Each unit will accommodate up to 7 type T thermocouple sensors and multiple Thermes units may be connected to the same computer for more thermocouple inputs. A high accuracy electronic cold junction compensation circuit maintains typical system accuracy of ±0.2°C over an ambient temperature range of 15 to 35°C. Individual offsets may be added to each input in software to facilitate individual calibration of each channel. For information on our wide selection of Type T Thermocouple temperature probes.

  • Audio Test Software

    Soft Hearts LLC

    1. Distortion free stimulus even the equalized stimulus.2. Unlimited channels acquisition and processing. (Hardware limited)3. Human correlated listening test(Bark Scale intensity chart). (Requires large memory)4. Hi Res intensity chart for buzz/pop detection. (Requires large memory)5. Auto equalization method with target dBSPL accuracy.6. TCP client for test framework integration.7. Easy limits and logs development.8. Easy logs visualization module.9. Auto waveform alignment and triggering.(Upto single point alignment accuracy)10. Easy regression testing via TCP client.11. Standard Magnitude, Phase, THD, THD+N, Rubb&Buzz, Pink Noise, Noise Tests.12. Unlimited calibrations and equalization for scaling to different products and stations.13. Lowest test system and test sequence development times.14. Requires minimal training and debugging.15. Automatically avoid Reference speaker play and stop pops.16. WMD/ASIO driver compatible sound cards supported.(B&K 3670 recommended)

  • Current Detectors

    PCE Instruments

    On our website you will find current detectors that are ideal for measuring AC or DC voltage. Current detectors are irreplaceable for inspection work and maintenance. We offer the following: voltage detectors, voltage leak detectors, voltage power detectors, Current clamps ideal for measuring AC or DC voltage. metric detectors, current detectors and more. These high quality current detectors include the capacity to measure many other parameters, such as capacity, resistance, power (both by way of clamps or by means of a hand held digital device with external clamps with a range of one or three stages). The current detectors are like the majority of our measurement instruments in that they meet and excel ISO standards. This calibration is done in a laboratory and comes with an accompanying certificate. All of our current detectors can perform the demanding tasks in each industrial sector regardless of the technical problem you encounter. If you can't find the current detectors you are looking for, please contact us and we will help you find the best solution to suit your needs by calling our offices on: UK customers +44(0) 23 809 870 30 / US customers (561) 320-9162 and our technical staff will advise you regarding our measuring instruments. Our engineers and technicians will be happy to help you with the current

Get Help